Raven Cruizer II Manual do Operador Página 17

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 16
Manual No. 016-0171-093 11
SmartBoom Operation
4
Standard SmartBoom Job
The simplest way to use SmartBoom is to simply start a job and begin spraying. SmartBoom will
generate an as-applied map of spray activity. If you enter an area that has already been sprayed,
SmartBoom will automatically turn off the boom or booms that have entered the previously sprayed
area.
SmartBoom Job with Field Boundary
If you are concerned about not applying any product outside of a field, you can create a no spray field
boundary when you start a job. Use the Create Field Boundary feature during an initial pass around a
field and SmartBoom monitors the location of the booms to create a field boundary. Once the field
boundary is created, SmartBoom will automatically create a no spray zone of at least three boom
widths around the field. During the rest of your application, SmartBoom will turn off any boom sections
that enter the no spray zone outside the field boundary.
SmartBoom Job with No Spray Zones
Some fields have features that you do not want to spray like waterways or well heads. SmartBoom
allows you to create up to eight no spray zones within a job. Simply select the no spray Zone Boundary
Menus and follow the instructions. Once you have told SmartBoom that you want to create a no spray
zone, you can continue to spray while you drive around the area on which you do not want to apply
product. SmartBoom will create a no spray zone within the area you have sprayed around. During the
rest of your application, SmartBoom will turn off any boom sections that enter this no spray zone.
SmartBoom Job with Field Boundary and No Spray Zones
For complete SmartBoom control, you can generate both a field boundary and up to eight no spray
zones for a job. Simply use the field boundary and no spray zone menus on the SmartBoom and spray
around the areas you do not want to spray. SmartBoom will create an as-applied map which includes a
no spray field boundary and up to eight no spray zones within the field boundary.
Additional SmartBoom Features
SmartBoom provides additional features to permit optimum coverage capabilities for your specific
application. These features include:
Look Ahead
Percent Coverage
Override